Jiangsu Panli environmental protection equipment co,Ltd.

Amca MemberIndustrial fan manufacturer

磐力风机 通过CNEX防爆 国家能效双重认证

玻璃钢除臭引风机运行中出现振动的因素及对策

作者: 来源: 发布日期: 2024-06-24 浏览次数:
信息摘要:
玻璃钢除臭引风机在运行时会出现风机振动、轴承气温过高、电动机电流过大或升温过高等故障,针对这些故障,小编总结了以下几点因素及对策:玻璃钢除臭引风机振动发生的因素通常有:风机轴与电动机轴差异心、机壳与叶…

       玻璃钢除臭引风机在运行时会出现风机振动、轴承气温过高、电动机电流过大或升温过高等故障,针对这些故障,小编总结了以下几点因素及对策:玻璃钢除臭引风机振动发生的因素通常有:风机轴与电动机轴差异心、机壳与叶轮摩擦、铆钉或螺栓松动、叶轮变形、轴承间隙过大、管道安装不良、皮带轮偏重或联轴器偏重、叶片有污垢或灰尘等。

玻璃钢除臭引风机厂家

       针对这些因素,磐力风机建议您定期清理灰尘污垢、定期检修、调节好各部件的间隙等。轴承升温过高轴承气温过高的通常是轴承箱振动强烈、润滑油或润滑脂编制或杂质较多、螺栓过紧或过松、轴承选用不当、玻璃钢除臭引风机冷却水中断或水量过小、轴承毁坏或前后两轴差异心等因素引起的。

       处理对策有:定期清洗轴承、箱体、主轴,更换润滑油或润滑脂,定期调节轴承或更换轴承,疏通冷却水调大水量等。

       玻璃钢除臭引风机电动机电流过大或升温过高,电动机电流过大或升温过高的因素通常是轴承毁坏、开车时出入气管自动道闸忘关或管道出现漏气、电动机输进电压低和电源单相断电、受轴承箱振动强烈的干扰、主轴转速比大于额定值、选用风机不合理等。

       处理对策有:调节电压正常接线、调节闸门堵塞出现漏气详尽位置、降低转速比、减小闸门开度控制点击电流、更换轴承等。咨询热线:0512-82870668

【相关推荐】
推荐资讯
Industrial ventilation fan

Industrial ventilation fan

Industrial fans are widely used in fiberglass processes, rare earth extraction, chemical and pharmaceutical industries, wastewater deodorization, anaerobic pape...
2024-06-24
Centrifugal ventilation fan

Centrifugal ventilation fan

Panli carbon steel ventilation fans have obtained various patent certifications and technical certifications for their high efficiency, high performance, low no...
2024-06-24
Protective net carbon steel fan

Protective net carbon steel fan

Panli carbon steel ventilation fans have obtained various patent certifications and technical certifications for their high efficiency, high performance, low no...
2024-06-24
Direct carbon steel fan

Direct carbon steel fan

Panli carbon steel ventilation fans have obtained various patent certifications and technical certifications for their high efficiency, high performance, low no...
2024-06-24
High temperature centrifugal fan

High temperature centrifugal fan

Technical parameters of high-temperature centrifugal ventilation fan: Fan model: THPA 8.0 D Fan air volume: 2924~6330 CMH Fan pressure: 11351~15276 Pa ...
2024-06-24

Enquiry hotline

0086-512-86878095 18351783102